rhf400
Share this product with friends

Whatsapp

Telegram

Facebook

Twitter

Email

Messanger

Temperature Sensor with Fermenter Connection

Model : RHF400

  1. Class A or higher accuracy
  2. Wetted parts made of SS316L
  3. Roughness value (Ra) ≤ 0.8 µm and ≤ 0.4 µm for non-wetted and wetted parts respectively
  4. SS304 terminal head and coupling nut
  5. EPDM sealing ring
  6. Operating pressure 10 bar
  7. Temperature range : Sensors tip -50 to 250°C (-58 to 482°F)
  8. Polyamide cable gland, M20x1.5 (M)
  9. Protection class, IP68 (NEMA 6P)
Read More...

Similar Products

RTS600
Transition joint Sanitary RTD Sensors |RTS600

  1. -50 to 250°C (-58 to 482°F)
  2. Class A / AA to IEC 60751 accuracy
  3. Pt100/Pt1000, 3-wire/4-wire Simplex/Duplex
  4. Roughness Value (Ra) ≤0.8 μm & ≤0.4 μm for Non-wetted and Wetted Parts Respectively
Read More...

rac243
RTD For Autoclave Validation |RAC243

  1. 0 to 150°C (32 to 302°F)
  2. Class A (1/2 DIN) accuracy
  3. Pt100, 3-wire/4-wire, Simplex/Duplex
  4. Cable length 3/5/10 m
  5. Sheath material SS316L (1.4404)
  6. Leakproof assembly
Read More...

rac232
RTD For Continuous Use In Autoclave |RAC232

  1. Range 0 to 180°C (32 to 356°F)
  2. Pt100, 4-wire Simplex/Duplex
  3. Class AA (1/3 DIN) to IEC 60751 accuracy
  4. Leakproof assembly
  5. Sheath material SS316L (1.4404)
  6. Cable length 5 / 10 m
Read More...

1
Signal Isolator, HART Compatible |SCC302

  1. HART compatible
  2. Accuracy : ±0.1% of span (±20 mA)
  3. 1500 VAC RMS galvanic isolation between supply, input & output
  4. 750 ohms load resistance
  5. Excitation supply for 2-wire transmitter
  6. Din rail mount
  7. 20-35 VDC supply
Read More...

Customers Also Viewed

nex206
Single/Dual Channel PID Controller, Full-featured, 96Wx96Hx60D, Output Power Display |NEX206

  1. Single/Dual loop PID/Heat+Cool PID/16-step profile control
  2. Universal input
  3. 5 relays, 2 isolated analog outputs, RS485/Modbus® RTU
  4. 3 digital inputs
  5. Field-selectable control device (relay/SSR/analog output)
Read More...

tx2dr
2-Wire, Isolated Temperature Transmitter - RTD Input |TX2DR

  1. Input : RTD Pt100, Pt50, Pt200, Pt500, Pt1000 (all 3-wire)
  2. Accuracy : ±0.1% of span
  3. Isolation : 1500 VAC
  4. Loop supply : 10 to 30 VDC
  5. 2-wire, 4~20mA analog output
Read More...

aqm201
Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus |AQM201

  1. Laser scatter method sensor for Particulate Matter measurement
  2. MEMS metal oxide semiconductor sensor to detect poor Air Quality
  3. NDIR CO2 sensor technology for superior stability in occupied and non-occupied buildings
  4. Measurement : Particulate Matter, TVOC, RH/T, CO2, CO, Air Quality Index
  5. Isolated RS485 Modbus® RTU output
  6. Dual relay output, 250 VAC-5A
  7. Field Replaceable PM, CO2, CO, TVOC, RH/T sensor
  8. RH/T sensor also provides the parameters like : Dewpoint, Absolute humidity, Heat index, Enthalpy, Air density
Read More...

csp201
Pulp Gauge |CSP201

  1. Scale ranges upto 0…40 bar
  2. Diaphragm material, SS316L
  3. Also available with flexible stainless steel armored capillary assembly.
Read More...

logo

loading