Radix RHW201 Industrial RTD with Protection Head
Radix RHW201 Industrial RTD with Protection Head
Radix RHW201 Industrial RTD with Protection Head
Radix RHW201 Industrial RTD with Protection Head
Radix RHW201 Industrial RTD with Protection Head
Share this product with friends

Whatsapp

Telegram

Facebook

Twitter

Email

Messanger

Industrial RTD with Protection Head

Model : RHW201

RHW201, Duplex, Flameproof, aluminium, threaded cap, Ex d, gas group IIB, IP67 (≈NEMA 6), T6, PESO, cable entry 2x1/2" NPT, Pt100, 3-wire, Class A, Adjustable compression fitting, SS304, 1/2" NPT, 6 mm (0.24"), 150 mm (5.90"), Cable gland, Blind plug, Terminal block, Not applicable, Not applicable, Not Applicalble, Not applicable, Not applicable, Not applicable

  1. -50 to 250°C (-58 to 482°F)
  2. Non-bendable sheath
  3. Class A or Class AA accuracy conforming to IEC 60751
  4. Standard lengths are 100, 150, 200 & 300mm (3.93, 5.90, 7.87, 11.81)"
  5. Weatherproof / Flameproof / ATEX aluminium head
  6. Adjustable or fixed threaded or flanged process connection
Read More...

Industrial RTD with Protection Head | RHW201 | Radix

Temperature Sensors, RTDs, RTD Sensors

Similar Products

Mineral Insulated RTD Probe | Radix Electrosystems
Mineral Insulated RTD Probe |RHW501

  1. Temperature ranges from -50 to 400 °C (-58 to 752ºF)
  2. Provided with various constructions
  3. Wide range of terminal heads for different applications
  4. Class A/AA accuracy
  5. Available in different diameters as per suitability to various applications
Read More...

RTD For Continuous Use In Autoclave | Radix Electrosystems
RTD For Continuous Use In Autoclave |RAC251

  1. 0 to 150°C (32 to 302°F)
  2. Class AA (1/3 DIN) accuracy
  3. Pt100, 3-wire, Simplex/Duplex
  4. Cable length 5/10 m
  5. Sheath material SS316L (1.4404)
Read More...

RTD For Continuous Use In Autoclave | Radix Electrosystems
RTD For Continuous Use In Autoclave |RAC232

  1. Range 0 to 180°C (32 to 356°F)
  2. Pt100, 4-wire Simplex/Duplex
  3. Class AA (1/3 DIN) to IEC 60751 accuracy
  4. Leakproof assembly
  5. Sheath material SS316L (1.4404)
  6. Cable length 5 / 10 m
Read More...

Industrial Thermocouples with Protection Head | Radix Electrosystems
Industrial Thermocouples with Protection Head |THW501

  1. Temperature ranges from 0 to 1150ºC (32 to 2102ºF)
  2. Provided with various mounting styles
  3. Wide range of terminal heads for different applications
  4. Standard/special limits of error (See Tables 5 & 6)
  5. Available in different diameters as per suitability to various applications
Read More...

Customers Also Viewed

2-wire Temperature Transmitter, Isolated, Head Mount, Programmable, Universal Input | Radix Electrosystems
2-wire Temperature Transmitter, Isolated, Head Mount, Programmable, Universal Input |SCC641

  1. 4-20 mA input (optional)
  2. 2-wire technology, 4-20 mA analog output
  3. High accuracy over total ambient temperature range
  4. Optical isolation
  5. An internal temperature sensor for active temperature compensation
  6. Wide supply voltage range
  7. User programmable measurement range settings
  8. Configuration with USB interface
  9. Simple and user friendly utility software
Read More...

Pressure Gauge Bourdon Type | Radix Electrosystems
Pressure Gauge Bourdon Type |PBE201

  1. All stainless steel construction
  2. Dry / liquid filled
  3. Better accuracy over the range
  4. Excellent load cycle stability and shock resistance
  5. Weatherproof to IP68 (NEMA≈4X) to IS/IEC 60529:2001
  6. Acceptable with diaphragm seal & other pressure gauge accessories
Read More...

Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus | Radix Electrosystems
Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus |AQM201

  1. Laser scatter method sensor for Particulate Matter measurement
  2. MEMS metal oxide semiconductor sensor to detect poor Air Quality
  3. NDIR CO2 sensor technology for superior stability in occupied and non-occupied buildings
  4. Measurement : Particulate Matter, TVOC, RH/T, CO2, CO, Air Quality Index
  5. Isolated RS485 Modbus® RTU output
  6. Dual relay output, 250 VAC-5A
  7. Field Replaceable PM, CO2, CO, TVOC, RH/T sensor
  8. RH/T sensor also provides the parameters like : Dewpoint, Absolute humidity, Heat index, Enthalpy, Air density
Read More...