Mineral Insulated RTD Probe

Model : RHW501

  1. Temperature ranges from -50 to 400 °C (-58 to 752ºF)
  2. Provided with various constructions
  3. Wide range of terminal heads for different applications
  4. Class A/AA accuracy
  5. Available in different diameters as per suitability to various applications
Read More...

Similar Products

5
Industrial RTD with Protection Head |RHW201

  1. -50 to 250°C (-58 to 482°F)
  2. Non-bendable sheath
  3. Class A or Class AA accuracy conforming to IEC 60751
  4. Standard lengths are 100, 150, 200 & 300mm (3.93, 5.90, 7.87, 11.81)"
  5. Weatherproof / Flameproof / ATEX aluminium head
  6. Adjustable or fixed threaded or flanged process connection
Read More...

3
Sanitary RTD |RHS600

  1. -50 to 250°C (-58 to 482°F)
  2. Class A / AA to IEC 60751 accuracy
  3. Pt100/Pt1000, 3-wire/4-wire Simplex/Duplex/Triplex
  4. Protection IP66/67/68 (≈NEMA 4X/6/6P)
Read More...

RTS600
Transition joint Sanitary RTD Sensors |RTS600

  1. -50 to 250°C (-58 to 482°F)
  2. Class A / AA to IEC 60751 accuracy
  3. Pt100/Pt1000, 3-wire/4-wire Simplex/Duplex
  4. Roughness Value (Ra) ≤0.8 μm & ≤0.4 μm for Non-wetted and Wetted Parts Respectively
Read More...

rac243
RTD For Autoclave Validation |RAC243

  1. 0 to 150°C (32 to 302°F)
  2. Class A (1/2 DIN) accuracy
  3. Pt100, 3-wire/4-wire, Simplex/Duplex
  4. Cable length 3/5/10 m
  5. Sheath material SS316L (1.4404)
  6. Leakproof assembly
Read More...

Customers Also Viewed

scr 4 group0
Three Phase SCR Power Controller For Resistive Load, 35 - 200 A |TPR-3P-48xxx-H

  1. Phase angle control technology
  2. 4-20 mA / 0-10V / 2-10V / 0-5V / 1-10V control input
  3. Suitable for three phase resistive load
  4. Configuration : Three phase star without neutral / closed delta
  5. Adjustable soft-start & soft control for smooth output voltage control
Read More...

3
Sanitary RTD |RHS600

  1. -50 to 250°C (-58 to 482°F)
  2. Class A / AA to IEC 60751 accuracy
  3. Pt100/Pt1000, 3-wire/4-wire Simplex/Duplex/Triplex
  4. Protection IP66/67/68 (≈NEMA 4X/6/6P)
Read More...

rac251
RTD For Continuous Use In Autoclave |RAC251

  1. 0 to 150°C (32 to 302°F)
  2. Class AA (1/3 DIN) accuracy
  3. Pt100, 3-wire, Simplex/Duplex
  4. Cable length 5/10 m
  5. Sheath material SS316L (1.4404)
Read More...

rac244
RTD With Molded Silicon Cable |RAC244

  1. 0 to 150°C (32 to 302°F)
  2. Class AA (1/3 DIN) accuracy
  3. Pt100, 3-wire/4-wire, Simplex/Duplex
  4. Cable length 5/10 m
  5. Sheath material SS316L (1.4404)
Read More...