3
2
rtt201
Share this product with friends

Whatsapp

Telegram

Facebook

Twitter

Email

Messanger

RTD Temperature Transmitter

Model : RTT201

  1. Dual 2-wire, 4-20 mA or dual 3-wire 0-10 VDC outputs
  2. Temperature range selection, parameter configuration and calibration with
  3. USB to serial converter (DCC501)
  4. Handheld configurator (HHC202) · Inbuilt LCD and 3 keys
  5. Health / status (Heartbeat) LED
  6. Isolated RS485 / MODBUS RTU or BACnet MS/TP
  7. High degree of protection against condensation & pollution
  8. Wall mount, duct mount & remote sensor option available
  9. 1/2" BSP adjustable compression fitting or triclover process connection option available
  10. Convenient installation with 2-part housing with fixed back and removable electronics
  11. Integral sensor (default) or remote sensor
Read More...

Similar Products

nex201
Single/Dual Channel PID Controller, Full-featured, 48Wx48Hx85D |NEX201

  1. Single/Dual loop PID/Heat+Cool PID/16-step profile control
  2. Universal input
  3. 5 relays, 2 isolated analog outputs, RS485 Modbus® RTU
  4. 3 digital inputs
  5. Field-selectable control device (relay/SSR/analog output)
Read More...

nex202
Single/Dual Channel PID Controller, Full-featured, 96Wx48Hx60D |NEX202

  1. Single / Dual loop PID / Heat+Cool PID / 16-step profile control
  2. Universal input
  3. 4 relays, 2 isolated analog outputs, RS485 Modbus® RTU
  4. 3 digital inputs
  5. Field-selectable control device (relay/SSR/analog output)
Read More...

nex205
Single/Dual Channel PID Controller, Full-featured, 96Wx96Hx60D |NEX205

  1. Single / Dual loop PID / Heat+Cool PID / 16-step profile control
  2. Universal input
  3. 5 relays, 2 isolated analog outputs, RS485/Modbus® RTU
  4. 6 digital inputs
  5. Field-selectable control device (relay/SSR/analog output)
Read More...

2
Humidity / Dewpoint / Temperature Transmitter, Wall & Duct |HTW201

  1. 2 x 2-wire, 4-20 mA or 0-10 VDC outputs
  2. Any output can be assigned to any parameter
  3. Configuration and calibration using PC with Radix converter DCC501
  4. Health/status LED
  5. Calculated parameters : Dewpoint, Absolute humidity, Heat index, Enthalpy
  6. Wall, Duct, Outside & Remote sensor versions
  7. Convenient installation with 2-part housing with fixed back and removable electronics
Read More...

Customers Also Viewed

scr 4 group0
Three Phase SCR Power Controller For Resistive Load, 35 - 200 A |TPR-3P-48xxx-H

  1. Phase angle control technology
  2. 4-20 mA / 0-10V / 2-10V / 0-5V / 1-10V control input
  3. Suitable for three phase resistive load
  4. Configuration : Three phase star without neutral / closed delta
  5. Adjustable soft-start & soft control for smooth output voltage control
Read More...

blind
Relative Humidity / Dewpoint / Temperature Transmitter, Wall |HTE201

  1. 2 x 2-wire, 4-20 mA or 0-10 VDC outputs with RTD resistance output option
  2. Any or both outputs can be assigned to RH or T or Dewpoint or specific derived physical quantity
  3. Configuration and calibration using PC with Radix converter DCC501
  4. Health / status (Heartbeat) LED
  5. Calculated parameters : Dewpoint, Absolute humidity, Heat index, Enthalpy
Read More...

1
Carbon Monoxide Transmitter, Wall Mount |CMW201

  1. User configurable CO ranges upto 1000 ppm
  2. Optional 4-digit dual row LCD display to display carbon monoxide value in ppm
  3. Heartbeat LED for device health status
  4. DIP selectable Loop powered current output or voltage output
  5. Optional dual 4-20 mA output
  6. IP65 (≈NEMA 3SX) protection for enclosure
  7. Wall mount arrangement
  8. Internal switch provided to adjust zero ppm
  9. DIP for range selection
Read More...

mld605
Multifunction Meter With LED Display, 96Wx96Hx62D |MLD605

  1. Power, Energy, Import/Export Energy, Dual Source
  2. Accuracy Class 1.0 as per IEC62052-11
  3. Modbus® RTU communication via RS-485 port
  4. Customized display with bar graph for load current
  5. Touch safe barrier terminals with terminal cover & sealing provisions
  6. Energy Reset option
  7. Dual Source input - Separate address for storing DG parameters
  8. RPM measurement, Load Hrs, ON Hrs measurement
  9. Field Programmable Star, Delta or Single Phase configuration
  10. Updating time of 1 second
  11. User settable display scroll time
  12. Password protected setup mode
  13. Wide-range AC/DC auxiliary power supply
Read More...