Analog Input Module
Share this product with friends

Whatsapp

Telegram

Facebook

Twitter

Email

Messanger

Analog Input Module

Model : SCM201

  1. 8 universal analog inputs
  2. Isolated RS485/MODBUS RTU, Upto 57600 Baud
  3. 85~265 VAC or 15-60 VDC supply
  4. 3 key, 3 level programming
  5. Powerful, flexible SCADA software available
  6. 4~20 mA output option (Tmax version with 4-20 mA for highest PV (from all channels)
  7. Standard & High Performance Version
Read More...

Similar Products

product HART, 2-wire Temperature Transmitter, Isolated, Universal Input, LCD Display, Flameproof
HART, 2-wire Temperature Transmitter, Isolated, Universal Input, LCD Display, Flameproof |SCC631

  1. Universal Input settings with HART protocol for various input signals
  2. 4-20 mA input (optional)
  3. 2-wire technology, 4-20 mA analog output
  4. High accuracy over total ambient temperature range
  5. Optical isolation
  6. An internal temperature sensor for active temperature compensation
  7. Wide supply voltage range
  8. User programmable measurement range settings
  9. Configuration with HART/USB interface
  10. Simple and user friendly utility software
Read More...

product Signal Isolator, Dual Outputs, 75(H)x45(W)x110(D)
Signal Isolator, Dual Outputs, 75(H)x45(W)x110(D) |SI4P

  1. 0/4-20 mA input
  2. 2x0/4-20 mA output
  3. Input, output isolation
  4. 22 VDC transmitter supply
  5. Din-rail mount
Read More...

product Analog Input Module With Ethernet Port
Analog Input Module With Ethernet Port |SCM203

  1. 8 universal analog inputs
  2. 8 thermocouples, Pt100, 0~50 mV, 0/4-20 mA
  3. MODBUS / TCP & Telnet multidrop communication for PLC, SCADA.
  4. 15~60 V DC supply SIZE : 75 x 100 x 110
  5. 3 key, 3 level programming
  6. Powerful, flexible SCADA software available
  7. 4~20 mA output option
  8. Standard & High Performance Version
Read More...

product Analog Input Module With Channel-to-channel Isolation
Analog Input Module With Channel-to-channel Isolation |SCM211

  1. 4 isolated universal analog inputs
  2. Channel-to-channel isolation of 300 V AC
  3. 8 thermocouples, Pt100, 0-1V, 0-2V, 0-5V, 0-10V, 0-20 mA, 4-20 mA, digital input
  4. Isolated RS485/MODBUS RTU, upto 57600 Baud
  5. 85-265 VAC or 15-60 V DC supply
  6. 3 key, 3 level programming
  7. Powerful, flexible SCADA software available
  8. 4-20 mA output option for any one channel
  9. Tmax version with 4-20 mA for highest PV (from all channels)
Read More...

Customers Also Viewed

product Clean Room Monitor, LCD
Clean Room Monitor, LCD |Hawkeye PRO

  1. RH, Temperature & DP measurement
  2. 3 programmable alarms with visual annunciation
  3. Real Time Clock with battery back-up
  4. No-touch operation for alarm acknowledge
  5. Potential free output contacts for alarm acknowledge
  6. Suitable for 50mm modular panel
  7. RS485/Modbus RTU multidrop communication for PLC, SCADA, etc.
Read More...

product Dual Relative Humidity / Temperature 2-Wire Output Transmitter, Wall & Duct
Dual Relative Humidity / Temperature 2-Wire Output Transmitter, Wall & Duct |RHT861

  1. 4 analog isolated outputs with true 2-wire operation, 2 RH, 2 T, 4 RH, 4 T
  2. Isolation : 1500 VAC RMS, 50 Hz/1 minute
  3. Precision Class A Pt100, Pt500, Pt1000 or band gap temperature sensor options
  4. Accuracy ±2% RH, ±0.5 deg C for band gap & ±0.2 deg C for RTD Class A sensor
  5. Any number of outputs (1-4) can be assigned to any parameter : RH, T or dew point
  6. Dual row 7 segment LCD option to display Relative Humidity, Temperature or Dew point (programmable)
  7. Parameter configuration via LCD & keys or remote display module or PC configurator using USB to Serial Converter DCC501
Read More...

product RTD Temperature Transmitter
RTD Temperature Transmitter |RTT201

  1. Dual 2-wire, 4-20 mA or dual 3-wire 0-10 VDC outputs
  2. Temperature range selection, parameter configuration and calibration with
  3. USB to serial converter (DCC501)
  4. Handheld configurator (HHC202) · Inbuilt LCD and 3 keys
  5. Health / status (Heartbeat) LED
  6. Isolated RS485 / MODBUS RTU or BACnet MS/TP
  7. High degree of protection against condensation & pollution
  8. Wall mount, duct mount & remote sensor option available
  9. 1/2" BSP adjustable compression fitting or triclover process connection option available
  10. Convenient installation with 2-part housing with fixed back and removable electronics
  11. Integral sensor (default) or remote sensor
Read More...

product Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus
Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus |AQM201

  1. Laser scatter method sensor for Particulate Matter measurement
  2. MEMS metal oxide semiconductor sensor to detect poor Air Quality
  3. NDIR CO2 sensor technology for superior stability in occupied and non-occupied buildings
  4. Measurement : Particulate Matter, TVOC, RH/T, CO2, CO, Air Quality Index
  5. Isolated RS485 Modbus® RTU output
  6. Dual relay output, 250 VAC-5A
  7. Field Replaceable PM, CO2, CO, TVOC, RH/T sensor
  8. RH/T sensor also provides the parameters like : Dewpoint, Absolute humidity, Heat index, Enthalpy, Air density
Read More...