Analog Input Module With Ethernet Port

Model : SCM203

  1. 8 universal analog inputs
  2. 8 thermocouples, Pt100, 0~50 mV, 0/4-20 mA
  3. MODBUS / TCP & Telnet multidrop communication for PLC, SCADA.
  4. 15~60 V DC supply SIZE : 75 x 100 x 110
  5. 3 key, 3 level programming
  6. Powerful, flexible SCADA software available
  7. 4~20 mA output option
  8. Standard & High Performance Version
Read More...

Similar Products

si4p
Signal Isolator, Dual Outputs, 75Hx45Wx110D |SI4P

  1. 0/4-20 mA input
  2. 2x0/4-20 mA output
  3. Input, output isolation
  4. 22 VDC transmitter supply
  5. Din-rail mount
Read More...

si3p
3-Port Signal Isolator, 75Hx55Wx11D |SI3P

  1. 0/4-20 mA input
  2. 2x0/4-20 mA output
  3. Input, output isolation
  4. 22 VDC transmitter supply
  5. Din-rail mount
Read More...

scm201
Analog Input Module |SCM201

  1. 8 universal analog inputs
  2. Isolated RS485/MODBUS RTU, Upto 57600 Baud
  3. 85~265 VAC or 15-60 VDC supply
  4. 3 key, 3 level programming
  5. Powerful, flexible SCADA software available
  6. 4~20 mA output option (Tmax version with 4-20 mA for highest PV (from all channels)
  7. Standard & High Performance Version
Read More...

scm211
Analog Input Module With Channel-to-channel Isolation |SCM211

  1. 4 isolated universal analog inputs
  2. Channel-to-channel isolation of 300 V AC
  3. 8 thermocouples, Pt100, 0-1V, 0-2V, 0-5V, 0-10V, 0-20 mA, 4-20 mA, digital input
  4. Isolated RS485/MODBUS RTU, upto 57600 Baud
  5. 85-265 VAC or 15-60 V DC supply
  6. 3 key, 3 level programming
  7. Powerful, flexible SCADA software available
  8. 4-20 mA output option for any one channel
  9. Tmax version with 4-20 mA for highest PV (from all channels)
Read More...

Customers Also Viewed

aqm201
Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus |AQM201

  1. Laser scatter method sensor for Particulate Matter measurement
  2. MEMS metal oxide semiconductor sensor to detect poor Air Quality
  3. NDIR CO2 sensor technology for superior stability in occupied and non-occupied buildings
  4. Measurement : Particulate Matter, TVOC, RH/T, CO2, CO, Air Quality Index
  5. Isolated RS485 Modbus® RTU output
  6. Dual relay output, 250 VAC-5A
  7. Field Replaceable PM, CO2, CO, TVOC, RH/T sensor
  8. RH/T sensor also provides the parameters like : Dewpoint, Absolute humidity, Heat index, Enthalpy, Air density
Read More...

PLC401
Loop Powered LCD Indicator |PLC401

  1. 4-20 mA loop current input
  2. HART protocol transparent
  3. Operational mode : Linear or square root, user programmable
  4. Accuracy : 0.1% of span, typical
  5. Loop voltage drop : <5 V
Read More...

pfs202
Paddle Type Flow Switch |PFS201

  1. High accuracy over the range
  2. Precisely field adjustable set flow setting
  3. Quick response to flow
  4. IIA/IIB, IP67 (NEMA 6) certified
  5. CCoE/PESO approved
Read More...

SPP17
Voltage Protection Relay, 3-Phase, Variable Reset Delay |SPP17

  1. Over Voltage Detection
  2. Under Voltage Detection
  3. Phase Unbalance / Asymmetry Detection
  4. Phase Reversal Detection
  5. Phase Loss Detection
Read More...