Radix TBR601 Triclover Parallel Shank Thermowell
Share this product with friends

Whatsapp

Telegram

Facebook

Twitter

Email

Messanger

Triclover Tapered Tip Thermowell

Model : TBR602

TBR602, SS316, 16 mm, 12 mm, 6.5 mm, 50 mm, 150 mm, 195 mm, 1" / 1 1/2" (50.4 mm) Triclover, 1/2" BSP (F) / 1/2" NPT (F) / 1/2" BSPT (F)

  1. Heavy duty design
  2. Deep hole drilling
  3. Coating/Lining/Sleeve for corrosive or abrasive process
  4. Wake Frequency as per ASME PTC 19.6
  5. Plant construction
Read More...

Triclover Tapered Tip Thermowell | TBR602 | Radix

Similar Products

Threaded Parallel Shank Thermowell | Radix Electrosystems
Threaded Parallel Shank Thermowell |TBR200

  1. Heavy duty design
  2. Deep hole drilling
  3. Coating/Lining/Sleeve for corrosive or abrasive process
  4. Wake Frequency as per ASME PTC 19.6
  5. Plant construction
Read More...

Stepped Shank Thermowell | Radix Electrosystems
Stepped Shank Thermowell |TBR201

  1. Heavy duty design
  2. Deep hole drilling
  3. Coating/Lining/Sleeve for corrosive or abrasive process
  4. Wake Frequency as per ASME PTC 19.6
  5. Plant construction
Read More...

Customers Also Viewed

Clean Room Monitor, 3 Row | Radix Electrosystems
Clean Room Monitor, 3 Row |Hawkeye-3 Row

  1. 3 channel RH, Temperature & DP measurement
  2. Potential free digital input for AHU status
  3. 3 programmable alarms with visual annunciation
  4. No-touch operation for alarm acknowledge
  5. 3 x 4-20 mA or 0-10 V analog output
  6. RS485 Modbus® RTU
  7. 18-35 VDC supply
  8. 3-digit, 0.8” seven segment display
  9. Datalogging feature
  10. Process value, alarm and time stamp logging
  11. Memory for 31 days with 1 minute datalogging interval
  12. Full datalogging control through utility
Read More...

Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus | Radix Electrosystems
Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus |AQM201

  1. Laser scatter method sensor for Particulate Matter measurement
  2. MEMS metal oxide semiconductor sensor to detect poor Air Quality
  3. NDIR CO2 sensor technology for superior stability in occupied and non-occupied buildings
  4. Measurement : Particulate Matter, TVOC, RH/T, CO2, CO, Air Quality Index
  5. Isolated RS485 Modbus® RTU output
  6. Dual relay output, 250 VAC-5A
  7. Field Replaceable PM, CO2, CO, TVOC, RH/T sensor
  8. RH/T sensor also provides the parameters like : Dewpoint, Absolute humidity, Heat index, Enthalpy, Air density
Read More...

In-Line Flow Switch | Radix Electrosystems
In-Line Flow Switch |LFS201

  1. Better accuracy over the range
  2. Precisely field adjustable set flow setting
  3. Quick sensitivity to flow
  4. Easy to install
  5. Scale for medium
Read More...