Temperature Uniformity Survey (TUS) Thermocouples
Share this product with friends

Whatsapp

Telegram

Facebook

Twitter

Email

Messanger

Temperature Uniformity Survey (TUS) Thermocouples

Model : TTN500

  1. Non-expendable thermocouple
  2. Compliant with AMS2750E & CQI-9
  3. Available in K & N thermocouple
  4. 20 & 18 SWG conductors as standard
  5. Glass fiber insulated
Read More...

Similar Products

product Temperature Transmitter for HVAC
Temperature Transmitter for HVAC |TTA201

  1. Input : Pt100, Pt1000
  2. Accuracy : ±0.3°C
  3. Output : 4-20 mA, 0-10VDC, 0-5VDC, 0-1VDC
  4. Unit : °C or °F
  5. Enclosures : Space, Wall, Duct, Outside Air
Read More...

product Transition Joint Thermocouple
Transition Joint Thermocouple |TTJ500

  1. Upto 1150°C range
  2. Available in K, N, J & T type thermocouple
  3. Sheath material SS316, SS310, Inconel 600
  4. Termination PTFE / Fiber glass insulated cable
  5. Sheath diameter 1.5 mm, 2 mm, 3 mm, 4.5 mm, 6 mm, 8 mm, 10 mm
  6. Sheath length upto 30 m
Read More...

product Control Thermocouple
Control Thermocouple |TCA200

  1. Upto 1150°C range
  2. Compliant with AMS2750E & CQI-9
  3. Available in K & N thermocouple
  4. Sheath material SS316, SS310, Inconel 600
  5. Termination die cast aluminium
  6. Standard tube diameter 21.3 mm
Read More...

product System Accuracy Test (SAT) Thermocouple
System Accuracy Test (SAT) Thermocouple |SAT200

  1. Upto 1150°C range
  2. Compliant with AMS2750E & CQI-9
  3. NABL accredited calibration certificate
  4. Available in K & N thermocouple
  5. Sheath material SS316, SS310, Inconel 600
  6. Termination standard male connector
  7. Sheath diameter 3 mm, 4.5 mm, 6 mm
Read More...

Customers Also Viewed

product HART, 2-wire Temperature Transmitter, Isolated, Universal Input, LCD Display, Flameproof
HART, 2-wire Temperature Transmitter, Isolated, Universal Input, LCD Display, Flameproof |SCC631

  1. Universal Input settings with HART protocol for various input signals
  2. 4-20 mA input (optional)
  3. 2-wire technology, 4-20 mA analog output
  4. High accuracy over total ambient temperature range
  5. Optical isolation
  6. An internal temperature sensor for active temperature compensation
  7. Wide supply voltage range
  8. User programmable measurement range settings
  9. Configuration with HART/USB interface
  10. Simple and user friendly utility software
Read More...

product Clean Room Monitor, 3 Row
Clean Room Monitor, 3 Row |Hawkeye-3 Row

  1. Relative Humidity, Temperature & Differential Pressure measurement
  2. Datalogging : Memory for 31 days with 1 minute datalogging interval
  3. RS485/MODBUS RTU multidrop communication for PLC, SCADA, etc.
  4. 3 programmable Alarms with visual annunciation
  5. Real Time Clock with battery back-up
  6. No-touch operation for alarm acknowledge
Read More...

product Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus
Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus |AQM201

  1. User configurable CO ranges upto 1000 ppm
  2. Optional 4-digit dual row LCD display to display carbon monoxide value in ppm
  3. Laser scatter method sensor for particulate matter measurement
  4. MEMS metal oxide semiconductor sensor to detect poor Air Quality
  5. Measurement : Particulate Matter, TVOC, RH/T, CO2, CO, Air Quality Index
  6. Dual relay output, 250 VAC-5A
  7. RH/T sensor also provides the parameters listed below :
  8. Dewpoint
  9. Absolute humidity
  10. Heat index
  11. Enthalpy
  12. Air density
Read More...

product Multifunction Meter With LED Display, 96Wx96Hx62D
Multifunction Meter With LED Display, 96Wx96Hx62D |MLD605

  1. Power, Energy, Import/Export Energy, Dual Source
  2. Accuracy Class 1.0 as per IEC62052-11
  3. Modbus® RTU communication via RS-485 port
  4. Customized display with bar graph for load current
  5. Touch safe barrier terminals with terminal cover & sealing provisions
  6. Energy Reset option
  7. Dual Source input - Separate address for storing DG parameters
  8. RPM measurement, Load Hrs, ON Hrs measurement
  9. Field Programmable Star, Delta or Single Phase configuration
  10. Updating time of 1 second
  11. User settable display scroll time
  12. Password protected setup mode
  13. Wide-range AC/DC auxiliary power supply
Read More...

;